Tecumseh HGA5512EXV Performance Data Sheet

Browse online or download Performance Data Sheet for Unknown Tecumseh HGA5512EXV. Tecumseh HGA5512EXV Performance Data Sheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Performance Data Sheet
HGA5512EXV
General Information
Model HGA5512EXV Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 265V ~ 60HZ
Return Gas 35°C (95°F) RETURN GAS Motor Type PSC
Performance Information
Condensing Temperature (°C)
Evap
Temp (°C)
30 40 50 60
Btu/h 6610
Watts (Power)
Amps 2.81
-25
Lb/h 90.5
Btu/h 6790 7230
Watts (Power)
Amps 2.83 2.67
-23.3
Lb/h 92.9 98.9
Btu/h 7180 7170
Watts (Power)
Amps 2.86 2.76
-20
Lb/h 98.3 98.1
Btu/h 7870 7330 7650
Watts (Power) 197 278 370
Amps 2.91 2.90 3.32
-15
Lb/h 108 100 105
Btu/h 8720 7840 7590 8060
Watts (Power) 495 589 693 825
Amps 2.93 3.02 3.51 4.07
-10
Lb/h 119 107 104 110
Btu/h 9380 8380 7860 7900
Watts (Power) 611 715 828 968
Amps 2.93 3.08 3.63 4.22
-6.7
Lb/h 128 115 108 108
Btu/h 9760 8730 8100 7960
Watts (Power) 650 760 877 1020
Amps 2.92 3.11 3.68 4.30
-5
Lb/h 134 120 111 109
Btu/h 11000 10000 9190 8630
Watts (Power) 700 828 962 1120
Amps 2.88 3.16 3.82 4.50
0
Lb/h 151 137 126 118
Page view 0
1 2

Summary of Contents

Page 1 - Performance Data Sheet

Performance Data SheetHGA5512EXVGeneral InformationModel HGA5512EXV Refrigerant R-22Test Condition ASHRAE Performance Test Voltage 265V ~ 60HZReturn G

Page 2 - Tc = Condensing Temperature

Btu/h 12500 11800 10900 10100Watts (Power) 683 831 984 1160Amps 2.78 3.17 3.91 4.655Lb/h 172 161 150 139Btu/h 13300 12700 11900 11000Watts (Power) 664

Comments to this Manuals