Tecumseh RKB5513EXA Performance Data Sheet

Browse online or download Performance Data Sheet for Unknown Tecumseh RKB5513EXA. Tecumseh RKB5513EXA Performance Data Sheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Performance Data Sheet
RKB5513EXA
General Information
Model RKB5513EXA Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 4710 4420
Watts 571 627
Amps 4.65 5.16
-15
Lb/h 60.6 59.3
Btu/h 5210 4890 4590
Watts 586 646 706
Amps 4.77 5.32 5.89
-10
Lb/h 66.6 65.1 63.8
Btu/h 5790 5450 5110 4790
Watts 601 664 728 792
Amps 4.89 5.49 6.11 6.74
-5
Lb/h 73.7 72.1 70.6 69.1
Btu/h 6470 6090 5730 5370 5030
Watts 616 682 750 818 887
Amps 5.01 5.66 6.33 7.00 7.70
0
Lb/h 81.8 80.1 78.4 76.8 75.3
Btu/h 7240 6830 6430 6030 5650
Watts 631 700 771 844 917
Amps 5.13 5.83 6.54 7.26 7.99
5
Lb/h 91.0 89.2 87.4 85.6 83.9
Btu/h 8110 7660 7210 6780 6350 5940 5540
Watts 646 718 792 868 946 1030 1110
Amps 5.26 6.00 6.75 7.50 8.27 9.06 9.86
10
Lb/h 101 99.3 97.4 95.5 93.7 91.9 90.3
Btu/h 9060 8570 8090 7610 7140 6680 6230
Watts 661 735 812 892 974 1060 1140
Amps 5.38 6.17 6.95 7.75 8.55 9.37 10.2
15
Lb/h 112 110 108 106 104 103 101
Btu/h 10100 9570 9050 8530 8010 7500 7000
Watts 676 752 832 916 1000 1090 1180
Amps 5.51 6.33 7.16 7.98 8.82 9.67 10.5
20
Lb/h 125 123 121 118 116 114 112
Page view 0