Performance Data Sheet
HGA5479BXC
General Information
Model HGA5479BXC Refrigerant R-410A
Test Condition ASHRAE Performance Test Voltage 220V ~ 50HZ
Return Gas -6.7°C (20°F) SUPERHEAT Motor Type PSC
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 2330 2210
Watts 355 385
Amps 1.73 1.85
-15
Lb/h 25.8 25.6
Btu/h 2610 2490 2320
Watts 364 397 422
Amps 1.75 1.90 2.00
-10
Lb/h 29.2 29.3 28.8
Btu/h 2930 2800 2630 2400
Watts 370 408 436 460
Amps 1.77 1.94 2.06 2.16
-5
Lb/h 33.0 33.1 32.8 31.7
Btu/h 3290 3140 2960 2730 2420
Watts 375 417 449 477 506
Amps 1.79 1.98 2.12 2.24 2.35
0
Lb/h 37.2 37.4 37.1 36.1 34.1
Btu/h 3690 3520 3320 3070 2750
Watts 379 424 459 491 524
Amps 1.80 2.00 2.17 2.31 2.44
5
Lb/h 41.9 42.0 41.8 40.9 38.9
Btu/h 4130 3940 3710 3440 3100 2680 2150
Watts 380 429 468 504 540 582 636
Amps 1.80 2.02 2.20 2.36 2.52 2.70 2.92
10
Lb/h 47.1 47.1 46.9 46.0 44.1 41.0 36.2
Btu/h 4630 4390 4140 3840 3480 3030 2480
Watts 379 432 475 514 554 600 657
Amps 1.79 2.03 2.23 2.41 2.59 2.80 3.04
15
Lb/h 52.9 52.9 52.5 51.6 49.8 46.7 42.0
Btu/h 5170 4900 4600 4270 3870 3400 2830
Watts 376 433 480 522 566 615 676
Amps 1.78 2.03 2.25 2.45 2.65 2.88 3.15
20
Lb/h 59.5 59.3 58.8 57.8 55.9 52.9 48.2
Page view 0
1 2

Summary of Contents

Page 1 - Performance Data Sheet

Performance Data SheetHGA5479BXCGeneral InformationModel HGA5479BXC Refrigerant R-410ATest Condition ASHRAE Performance Test Voltage 220V ~ 50HZReturn

Page 2 - Tc = Condensing Temperature

Btu/h 5770 5450 5110 4730 4300 3790 3180Watts 371 431 482 528 576 629 693Amps 1.76 2.03 2.26 2.48 2.70 2.95 3.2425Lb/h 66.9 66.4 65.8 64.6 62.7 59.6 5