Tecumseh AEA2413AXA Performance Data Sheet

Browse online or download Performance Data Sheet for Unknown Tecumseh AEA2413AXA. Tecumseh AEA2413AXA Performance Data Sheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Performance Data Sheet
AEA2413AXA
General Information
Model AEA2413AXA Refrigerant R-12
Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ
Return Gas 32.2°C (90°F) RETURN GAS Motor Type CSIR
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 597 555 491 404 297 170 22.4
Watts 256 256 249 236 215 187 152
Amps 4.38 4.37 4.35 4.32 4.27 4.20 4.10
-40
Lb/h 10.5 9.33 8.00 6.48 4.70 2.63 0.19
Btu/h 723 687 629 551 453 337 201
Watts 273 275 272 263 247 225 195
Amps 4.41 4.41 4.40 4.38 4.34 4.28 4.20
-35
Lb/h 12.5 11.4 10.2 8.83 7.23 5.34 3.11
Btu/h 859 827 776 706 617 510 386
Watts 290 294 294 288 277 260 236
Amps 4.46 4.46 4.46 4.44 4.41 4.37 4.30
-30
Lb/h 14.6 13.6 12.6 11.3 9.86 8.15 6.10
Btu/h 1010 979 933 870 789 692 578
Watts 307 313 315 313 305 293 275
Amps 4.51 4.52 4.52 4.51 4.50 4.46 4.41
-25
Lb/h 16.9 16.0 15.1 13.9 12.6 11.1 9.21
Btu/h 1170 1140 1100 1040 971 882 779
Watts 324 332 336 337 333 325 312
Amps 4.57 4.58 4.59 4.59 4.59 4.57 4.53
-20
Lb/h 19.5 18.7 17.8 16.8 15.6 14.2 12.4
Btu/h 1340 1320 1280 1230 1160 1080 990
Watts 342 351 357 360 360 355 347
Amps 4.64 4.65 4.67 4.68 4.69 4.68 4.65
-15
Lb/h 22.3 21.5 20.7 19.8 18.7 17.4 15.8
Btu/h 1530 1510 1480 1430 1370 1300 1210
Watts 361 370 378 383 386 385 381
Amps 4.71 4.74 4.76 4.78 4.80 4.80 4.79
-10
Lb/h 25.4 24.6 23.9 23.0 22.0 20.9 19.4
Btu/h 1740 1720 1690 1650 1590 1520 1450
Watts 381 391 399 406 412 414 414
Amps 4.80 4.83 4.86 4.89 4.92 4.93 4.94
-5
Lb/h 28.8 28.0 27.3 26.5 25.6 24.5 23.2
Page view 0
1 2

Summary of Contents

Page 1 - Performance Data Sheet

Performance Data SheetAEA2413AXAGeneral InformationModel AEA2413AXA Refrigerant R-12Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZReturn G

Page 2 - Tc = Condensing Temperature

Btu/h 1960 1950 1920 1880 1830 1770 1700Watts 402 412 422 430 438 443 446Amps 4.90 4.93 4.97 5.01 5.05 5.08 5.100Lb/h 32.5 31.8 31.1 30.3 29.5 28.5 27

Comments to this Manuals

No comments