Performance Data Sheet
AWJ5532EVA
General Information
Model AWJ5532EVA Refrigerant R-22
Test Condition ARI Performance Test Voltage 220V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 7210 6630
Watts 1260 1280
Amps 7.71 7.82
-15
Lb/h 103 95.4
Btu/h 8710 8030 7350
Watts 1320 1350 1380
Amps 7.83 7.98 8.12
-10
Lb/h 120 112 103
Btu/h 10300 9560 8770 7980
Watts 1380 1420 1470 1510
Amps 7.96 8.15 8.35 8.54
-5
Lb/h 138 130 121 113
Btu/h 12100 11200 10300 9430 8540
Watts 1440 1490 1550 1610 1670
Amps 8.10 8.35 8.59 8.83 9.07
0
Lb/h 158 149 141 133 124
Btu/h 14100 13100 12000 11000 10000
Watts 1490 1560 1630 1700 1770
Amps 8.25 8.55 8.85 9.14 9.43
5
Lb/h 180 171 163 154 145
Btu/h 16200 15000 13900 12800 11600 10500 9410
Watts 1540 1630 1710 1800 1880 1960 2040
Amps 8.41 8.76 9.11 9.45 9.79 10.1 10.5
10
Lb/h 204 195 186 177 168 159 150
Btu/h 18500 17200 15900 14700 13400 12200 10900
Watts 1590 1690 1790 1880 1980 2070 2170
Amps 8.56 8.97 9.37 9.77 10.2 10.6 10.9
15
Lb/h 231 222 212 203 194 184 175
Btu/h 21000 19600 18200 16800 15400 14000 12600
Watts 1640 1750 1860 1970 2080 2190 2290
Amps 8.71 9.18 9.64 10.1 10.5 11.0 11.4
20
Lb/h 260 250 241 231 221 211 202
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Performance Data Sheet

Performance Data SheetAWJ5532EVAGeneral InformationModel AWJ5532EVA Refrigerant R-22Test Condition ARI Performance Test Voltage 220V ~ 50HZReturn Gas

Page 2 - Tc = Condensing Temperature

Btu/h 23700 22200 20600 19000 17500 16000 14500Watts 1670 1800 1930 2050 2170 2300 2420Amps 8.85 9.38 9.90 10.4 10.9 11.4 11.925Lb/h 292 281 271 261 2

Page 3

Performance Data SheetAWJ5532EVAGeneral InformationModel AWJ5532EVA Refrigerant R-22Test Condition ARI Performance Test Voltage 265V ~ 60HZReturn Gas

Page 4

Btu/h 28600 26700 24800 23000 21100 19300 17500Watts 2150 2280 2410 2540 2660 2780 2900Amps 8.52 9.03 9.53 10.0 10.5 11.0 11.525Lb/h 352 339 327 315 3